<< back to the offer

 

CBW-50 AND CBW-150 MULTI-OIL BURNERS

 

Multi-oil CBW burners are the best devices for the combustion of used oils and medium and light fuel oils in the power range from 30 to 150 kW. The power range for the CBW-50 burner is 30 to 100 kW, whereas 80 to 150 kW for the CBW-150 burner

Multi-oil CBW burners with syphon-type nozzle have oil and air heating system. Heated oil is dispersed compressed air, which is required for burner operation (it is necessary to purchase small compressor or use the existing one). Multi-oil burner is adapted for combustion of semi-heavy oils, vegetable oils, bio-fuels, used oils (engne, hydraulic, gear oils) and of course light fuel oils. Our burners are made from European parts of the highest quality from renown producers (Danfoss starter, Danfos control system, Delavan nozzle, Delta pump).
 

Kit includes the following accessories:

  1. Burner
  2. Pumping unit for fuel
  3. Thorough cleaning filter
  4. Check valve
  5. Initial cleaning filter
  6. Suction hose ends
  7. Oil and compressed air heating system
  8. Oil and compressed air pressure controls

Accessories required for burner start-up:

  1. Fuel tank
  2. Flexible fuel hose from oil-resistant rubber, with internal diameter of 16 mm, connecting tank and filter (available in shops with technical rubber products)
  3. Copper pipe with internal diameter of 15 mm, connecting pump and burner
  4. Compressor for producing compressed air, approx. 60 l/min @ 2.5bar
  5. Chimney
  6. Boiler or heater

     

TECHNICAL DATA:

MODEL:
CBW-50
CBW-150
POWER
Min kW
40
80
Max kW
100
150
FUEL
OLEJE OPAŁOWE 1,5-50 mm²/s
WYDATEK kg/h
3,43÷8,60
8,60÷17,19
POWER SUPPLY
V/Hz
240V/50Hz
POWER CONSUMPTION
kW
0,9
1,1
FAN MOTOR
0,18kW/2800min-1 (240V/50Hz)
PUMP MOTOR
0,18kW/1400 min-1 (240V/50Hz)
FUEL HEATER
W
400
700
FUEL PUMP
Oil pressure after reducer
DELTA V4LR13U
2÷10 PSI
0,1÷0,7 Bar
(dysza Dellavan
typ SN 30609-5)
2÷5 PSI
0,1÷0,35 Bar
(dysza Dellavan
typ SN 30609-11)
       

 

PUMPING UNIT INSTALLATION:

important: due to air flow, the filter should be directed downwards

(click on image to the enlarged view)

 

<< back to the offer
 